3GPP TS 27.007 AT COMMANDS
71 AT Commands for EV-DO-EV3 Modems
3 The module wakes up in "alarm mode" if at the alarm time it was off,
otherwise it remains fully operative. In both cases the module starts
playing the alarm tone on the selected path for the ringer. See #SRP.
The device keeps playing the alarm tone until a #WAKE or #SHDN
command is received or a 90 second timeout occurs. If the device is in
alarm mode and does not receive the #WAKE command within 90
seconds, it shuts down.
4 The module wakes up in "alarm mode" if at the alarm time it was off,
otherwise it remains fully operative. In both cases the module brings the
pin GPIO6 high, provided its <direction> is set to alarm output, and keeps
it in this state until a #WAKE or #SHDN command is received or a 90
seconds timer expires. If the device is in alarm mode and does not
receive the #WAKE command within 90 seconds, it shuts down.
5 The module makes both the actions as for type=2 and <type>=3.
6 The module makes both the actions as for type=2 and <type>=4.
7 The module makes both the actions as for type=3 and <type>=4.
8 The module wakes up in "alarm mode" if at the alarm time it was off,
otherwise it remains fully operative. In both cases the module sets High
the RI output pin. The RI output pin remains High until next #WAKE issue
or until a 90 second timer expires. If the device is in alarm mode and does
not receive the #WAKE command within 90 seconds, it shuts down.
<text> Unsolicited alarm code text string. It has meaning only if <type> is equal
to 2, 5 or 6.
<recurr> String type, value indicating day of week for the alarm in one of the
following formats:
“<1..7>[,<1..7>[, … ]]” Sets a recurrent alarm for one or more days in the week; the digits 1 to 7
corresponds to the days in the week. Monday is 1.
“0” Sets a recurrent alarm for all days in the week.
<silent> Integer type indicating if the alarm is silent or not.
0 The alarm is not silent.
1 The alarm is silent.
During the "alarm mode" the device does not make any network scan
and does not register to any network and therefore is not able to dial or
receive any call or SMS, the only commands that can be issued to the
module in this state are the #WAKE and #SHDN, every other command
must not be issued during this state.
Note: You must set the RTC (issuing +CCLK) at least once before you can
issue +CALA with <type>=8.
Notes
Reference: ETSI 07.07, ETSI 27.007.
Example
AT+CALA="02/09/07,23:30:00+00"
OK
AT+CALA="12/09/07,10:38:00+02",0,2,GO GET SOME COFFEE,"",0
AT+CALA?
+CALA: "12/09/07,10:38:00",0,2,"GOGETSOMECOFFEE","",0
OK