V.250 AT COMMANDS
41 AT Commands for EV-DO-EV3 Modems
Syntax
Command Command type
AT+IPR=<rate> Set
AT+IPR? Read
AT+IPR=? Test
Parameters and Values
<rate>
300
1200
2400
4800
9600
19200
38400
57600
115200 Default: 115200.
230400
460800
3200000
4000000
Notes
DTE speed of USB port is always 0. USB DTE speed does not change.
If <rate> is specified and not 0, DTE-DCE speed is fixed at that speed.
Rate can be higher than 115200. Maximum value depends on specific product. Check this value with
AT+IPR=?.
Reference: V.25ter.
DTE Modem Local Flow Control +IFC
Set command selects the serial port flow control behavior in both directions, from DTE to modem (<by_ta>
option) and from modem to DTE (<by_te>).
Read command returns active flow control settings.
Test command returns all supported values of the parameters <by_te> and <by_ta>.