Multitech CDMA Betriebsanweisung Seite 130

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 249
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 129
MULTISOCKET AT COMMA
NDS
AT Commands for EV-DO-EV3 Modems
130
Socket Configuration Extended #SCFGEXT
Set command sets the socket configuration extended parameters.
Read command returns the current socket extended configuration parameters values for all the six sockets, in the
format:
#SCFGEXT: <connID1>,<srMode1>,<dataMode1>,<keepalive1>,
<unused_A1>,<unused_B1><CR><LF>
...
#SCFGEXT: <connID6>,<srMode6>,<dataMode6>,<keepalive6>
<unused_A6>,<unused_B6>
Test command returns the range of supported values for all the subparameters.
Syntax
Command Command type
AT#SCFGEXT=<connID>,<srMode>,<dataMode>,<keepalive>,
[,<unused_A> [,<unused_B>]]
Set
AT#SCFGEXT? Read
AT#SCFGEXT=? Test
Parameters and Values
<connID> Socket connection identifier.
1-6
<srMode> SRing URC mode.
0 Normal mode. Default: 0.
SRING : <connID> where <connID> is the socket connection identifier.
1 Data amount.
SRING : <connID>,<recData> where <recData> is the amount of data received on the
socket connection number <connID>.
2 Data view.
SRING : <connID>,<recData>,<data> is received data, presentation format depends on
the subparameter.
<dataMode> Data view mode presentation format.
0 Text mode. Default: 0.
1 Hexadecimal mode (from 00 to FF).
<keepalive> Set the TCP Keepalive value in minutes.
0 Deactivated. Default: 0.
1 240 Keepalive time in minutes.
<unused_A> Currently unused.
0 Reserved for future use.
<unused_B> Currently unused.
0 Reserved for future use.
Seitenansicht 129
1 2 ... 125 126 127 128 129 130 131 132 133 134 135 ... 248 249

Kommentare zu diesen Handbüchern

Keine Kommentare