V.250 AT COMMANDS
49 AT Commands for EV-DO-EV3 Modems
Syntax
Command Command type
ATS7=[<tout>] Set
ATS7? Read
Parameters and Values
<tout> Number of seconds.
1-255 Default: 60.
Notes
Reference: V.25ter.
Escape Prompt Delay S12
Set command sets:
1. The minimum period, before the first of the three escape characters is received, during which no other
character has to be detected in order to accept it as a valid first character;
2. The maximum period allowed between receipt of first or second character of the three escape character
sequence and receipt of the next;
3. The minimum period, after receipt of the last character of the three escape character sequence, during
which no other character has to be detected in order to accept the escape sequence as a valid one.
Read command returns the current value of S12 parameter. The format of the numbers in output is always 3
digits, left-filled with 0s.
Syntax
Command Command type
ATS12=[<char>] Set
ATS12? Read
Parameters and Values
<time> Expressed in fiftieth of a second.
20-255 Default: 50.
Notes
The minimum period S12 has to pass after CONNECT result code too, before a received character is
accepted as valid first character of the three escape character sequence.
Reference: V.25ter.
Delay to DTR Off S25
Set command defines the amount of time, in hundredths of second, that the device ignores the DTR for taking the
action specified by command &D.
Read command returns the current value of S25 parameter. The format of the numbers in output is always 3