S-Registers
Certain modem values, or parameters, are stored in memory locations called S-registers.
Use the S command to read or to alter the contents of S-registers (see previous section).
Register Unit Range Default Description
S0 1 ring 0, 1–255 1 Sets the number of rings until the modem
answers. ATS0=0 disables autoanswer completely.
S1 1 ring 0–255 0 Counts the rings that have occurred.
S2 decimal 0–127 43 (+) Sets ASCII code for the escape sequence
128–255 character. Values greater than 127 disable
escape.
S3 decimal 0–127 13 (^M) Sets the ASCII code for the carriage return
character.
S4 decimal 0–127 10 (^J) Sets the ASCII code for the line feed
character.
S5 decimal 0–32 8 (^H) Sets the ASCII code for the backspace
33–127 character. Values greater than 32 disable
backspace.
S6 seconds 2–65* 2* Sets the time the modem waits after it goes
off-hook before it begins to dial the telephone
number.
S7 seconds 1–255* 50* Sets the time the modem waits for a carrier
signal before aborting a call. Also sets the wait
for silence time for the @ dial modifier.
S8 seconds 0–65 2 Sets the length of a pause caused by a
comma character in a dialing command.
S9 decimal 0, 1–127 37 (%) Sets ASCII code for remote configuration
escape character. S9=0 disables remote
configuration.
S10 100 ms 1–254 20 Sets how long a carrier signal must be lost
before the modem disconnects.
S11 1 ms 50–150* 95* Sets spacing and duration of dialing tones.
S28 decimal 0, 1–255 1 0 disables, 1–255 enables V.34 modulation.
S30 1 minute 0, 1–255 0 Sets the length of time that the modem waits
before disconnecting when no data is sent or
received. A value of zero disables the timer.
See also the \T command.
S35 decimal 0–1 0 0 disables, 1 enables the V.25 data calling
tone, which allows remote data/fax/voice
discrimination.
S36 decimal 0–7 7 Specifies the action to take in the event of a
negotiation failure when error control is
selected. (See S48.)
Seitenansicht 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 61 62

Kommentare zu diesen Handbüchern