Chapter 2 – Command Line Interface (CLI)
Command Line Interface and Application Examples for Multi-Tech Systems, Inc. IP Modules (S000368F) 12
General Commands – Setup
Command Syntax set date <DD/MM/YYYY>
Description
Sets the system date.
Default Value
Jan 1 1970
Success
OK
Error 1. Too few arguments
Usage: set date DD/MM/YYYY
Type 'set date ?' for more information
Error: Date in DD/MM/YYYY format
Too few arguments. Possible argument(s) are:
date login serial
ip ppp time
Command Syntax set login
Description
Prompts the Login for the command shell when enabled and doesn't when disabled.
Default Value
Enable
Success
OK
Error 1. Too few arguments
"Usage: set login <enable/disable>
Type 'set login ?' for more information"
2. Invalid string
"error: set login <enable/disable>"
Command Syntax set login auto-dialout-login <enable/disable>
Description
Enables/Disables authentication for Telnet auto-dialout.
Default Value
Disable
Success
OK
Error 1. Too few arguments
"Usage: set login auto-dialout-login <enable/disable>
Type 'set login auto-dialout-login ?' for more information"
2. Invalid string
"error: set login auto-dialout-login <enable/disable>"
Command Syntax set time <HH:MM:SS>
Description
Sets the system time.
Default Value
00:00:00
Success
OK
Error 1. Too few arguments
Usage: set date HH:MM:SS
Type 'set date ?' for more information
Error: Time in HH:MM:SS format
Too few arguments. Possible argument(s) are:
date login serial
ip ppp time
Command Syntax set watchdog <enable/disable>
Description
Enables/Disables the watchdog timer.
The timer value is set to 6.5 seconds. This is the upper threshold value.
Note: Watchdog timer comes into effect only after reboot. Hence,
invoking this command calls for a reboot on save.
Default Value
Enable
Success
OK
Error 1. Too few arguments
"Usage: set watchdog <enable/disable>
Type 'set watchdog <enable/disable> ?' for more information"
2. Invalid string
"error: set watchdog <enable/disable>"