Multi-Tech Communication Serial InterfaceFor Windows® 2000 & XPSoftware Installation Guide
Installation10b.) Accessing IPModule ports:Auto-discovery (MAG) protocol is used to discover and query status of IPModuleproducts. It uses the configu
Installation11II. When Direct is selected:a.) Accessing IPModule/RAS ports:No discovery mechanism. The specified server IP address/name is stored in
Installation1211. A completion screen will appear. You will be prompted to reboot the computer. Select Yes, I wantto restart my computer now.. Click F
Viewing Servers and Their Details13VIEWING SERVERS AND THEIR DETAILSBefore MCSI can discover the IP Modules, the AG Server has to be enabled. Perform
Viewing Servers and Their Details14STATUS OF THE DISCOVERED SERVERS:IP MODULE STATUS:The discovered IP Servers are displayed in the left window of the
Viewing Servers and Their Details15RAS PRODUCT STATUS:The discovered RAS product port status is displayed by clicking on the discovered server, e.g.,S
Viewing Servers and Their Details16AUTHENTICATION MECHANISM:RAS products:MCSI uses MAG protocol to negotiate login details with RAS products and chang
Viewing Servers and Their Details17Servers (IP Modules/RAS products) using Telnet/Raw modes:By default, MCSI displays all the discovered IP Modules wi
Viewing Servers and Their Details18IP MODULE MANUAL ADDITION TO LIST OF AG SERVERSGenerally, the UDP broadcasts are not forwarded; hence IPModules no
Viewing Port Details19VIEWING VIRTUAL PORT DETAILSThis screen shows the default status of the virtual ports before they are mapped to any of the serve
2Software Installation GuideMulti-Tech Communication Serial InterfaceMCSI2000S000361A Revision AThis publication may not be reproduced, in whole or in
Viewing Port Details20MAPPING VIRTUAL PORTS TO REMOTE SERVER PORTS1. Select a port on the remote server and a listing of the virtual ports will be di
Viewing Port Details21Choosing the Protocol:Two options are provided:¾ If Telnet option is selected, you could specify the port number configured in
Appendix22APPENDIXTelnet RFC 2217 Options in MCSITelnet Options in MCSI:• Terminal Type Option - (VT100 type: cannot be modified)• Terminal Speed Op
Appendix23y Use DCD Flow Control (Outbound / Both)y Use DTR Flow Control (Inbound)y Use DSR Flow Control (Outbound / Both)2) Set-Modem State-Mask
Appendix24Not-Supported options:1) Control Options:1) Set-Line Status-Mask Option:y Time-out Errory Transfer shift register emptyy Transfer holdin
3MCSI2000INTRODUCTION... 4MCSI2000 Client ex
Introduction4INTRODUCTIONWelcome to Multi-Tech’s Communication Serial Interface (MCSI2000) which is a serial portredirector software for Windows® 2000
Installation5MCSI INSTALLATION PROCEDURETo install MCSI2000 on Windows 2000 and XP Operating Systems, perform the following procedure.1. Power on your
Installation66. A ‘System Requirements’ screen will appear. Verify that the PC meets the requirements. Click Next.7. The Choose Destination Location s
Installation78. The Setup Status screen appears while files are being copied.9. At the UserName & Password Required screen, create a User Name and
Installation810. The Add New Port screen appears.I. When Auto-Discovery (MAG) is selected:By default, the window shown below pops up when adding a ne
Installation9If Wild card mapping is enabled,a.) Accessing RAS ports:Auto-discovery (MAG) protocol is used to discover and query status of RAS product
Kommentare zu diesen Handbüchern