RSU INSTALLATION MANUAL 9
Chapter 3.
RSU Cable Preparation And Laying
3.1. INTRODUCTION
Following are the main cables required for RSU installation apart from the other
cables mentioned in C-DOT SBM RAX/DSS MAX-L/XL installation manual.
a. RSU Clock cable.
b. Digital Trunk Cables on RSU side.
c. Digital Trunk Cables on Central Module (CM) side.
d. BP Terminal cable on RSU side.
Co-axial cable is used to prepare the clock cable for RSU. Clock cable will be
connected between ETS (Enhanced Remote Time Switch) card slot position and TSC
(Time Switch Controller) card slot position on each copy of TSU. Since the
connections on the contact blocks at both ends are not one-to-one, care needs to be
taken by the installer while fixing it on the mother-board.
Digital Trunk Cable on RSU side is connected from Time Switch Unit to DDF. On
CM side, it is connected between Bus Termination Unit (BTU) and DDF. The shield
at DDF end of these cables are connected to chassis ground. Other end of the cable
shields (RBM and CM side) should be left open to isolate the ground.
Assembly of the digital trunk cable on RSU side also provides connection to an
ACIO cable. For ACIO part, jumper wire with PVC sleeve may be used.
BP terminal cable is optional only. This may be required for debugging switch units
in case RBM is totally cut off from the parent exchange and it is having critical
switch unit faults.
One CRP terminal is extended through modem on RSU side for maintenance
functions. This does not require any additional cables as Modem is normally
supplied alongwith a cable which is having D-type 25 pin connectors on both ends.