Multitech BL-Series Spezifikationen Seite 63

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 126
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 62
SIESPACE Reported Faults
406 Car Park: Loop Stuck
One of the detectors responsible for
counting vehicles into or out of the car
park is faulty. The detector is reporting a
vehicle is permentantly being detected -
this could mean a vehicle parked on an
entrance, or a loop having been
damaged. The SIESPACE instation will
revert to using historical occupancy
data.
407
Car Park: Loop Not
Detecting
One of the detectors responsible for
counting vehicles into or out of the car
park is faulty. The detector has not
reported a vehicle for a long time - this
could mean the entrance not being
used, or a loop having been damaged.
The SIESPACE instation will revert to
using historical occupancy data.
408 Car Park: Comms Error
The SIESPACE instation has not
received a status message from the car
park oustation according to the timetable
it is supposed to be using. This indicates
that communication has failed.
SIESPACE will attempt to re-establish
communication, as will the outstation,
but in the meantime, the SIESPACE
instation will revert to using historical
occupancy data.
file:///A|/html/reported_faults.htm (4 of 4) [27/06/2001 20:46:16]