LEDS, CONNECTORS, AND SPECIFICATIONS
Power Measurements
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into your power source when determining
product load.
Note: Note the following:
Maximum: The continuous current during maximum data rate with the radio transmitter at
maximum power.
Peak: The peak current during a transmission burst period.
In-rush Current: The input current during power up, or a reset.
MTCMR-H5
GSM 850
Idle Typical Maximum Peak TX In-rush Current
9 volts
Current (AMPS) 0.057 0.080 0.185 1.18 1.61
Watts 0.526 0.740 1.700
20 volts
Current (AMPS) 0.030 0.044 0.087 0.530 1.71
Watts 0.600 0.880 1.740
32 volts
Current (AMPS) 0.021 0.031 0.054 0.332 1.46
Watts 0.672 0.992 1.73
HSPA+
Idle Typical Maximum Peak TX In-rush Current
9 volts
Current (AMPS) 0.057 0.140 0.270 0.340 1.61
Watts 0.526 1.290 2.47
20 volts
Current (AMPS) 0.030 0.070 0.131 0.196 1.71
Watts 0.600 1.400 2.62
32 volts
Current (AMPS) 0.021 0.048 0.086 0.152 1.46
Watts 0.672 1.54 2.75