Multitech MT9234ZBAUSBCDC Betriebsanweisung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 66
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
Chapter 1 – AT Commands, S-Registers, and Result Codes
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H) 14
&C Data Carrier Detect (DCD) Control
Description: Use this command to control the modem’s response to receiving a remote modem's
carrier signal. Data carrier detect (DCD) is a signal from the modem to the computer
indicating that the carrier signal is being received from a remote modem. The modem
typically turns off DCD when it no longer detects the remote modem's carrier signal.
Syntax: AT&C<value>
Values: 0 DCD remains ON at all times.
1 DCD turns ON when the remote modem’s carrier signal is detected, and
turns OFF when the carrier signal is not detected.
Default: 1
Result Codes: OK if <value> = 0 to 1.
ERROR if <value> 0 to 1.
&D Data Terminal Ready (DTR) Control
Description: Use this command to select the modem’s response to the data terminal ready (DTR)
signal. The host system generates the DTR signal and supplies it to the modem.
Syntax: AT&D<value>
Values: 0 Modem ignores true status of DTR signal and treats it as always on. Use this
command if the computer does not provide DTR to the modem.
1 If DTR is not detected while in online data mode, the modem enters
command mode, issues an OK, and remains connected.
2 If DTR signal is not detected while in online data mode, the modem
disconnects.
3 Resets the modem on the on-to-off DTR transition.
Default: 2
Result Codes: OK if <value> = 0 to 3.
ERROR if <value> 0 to 3.
&E XON/XOFF Pacing Control
Description: Enables or disables XON/XOFF pacing.
Syntax: AT&E<value>
Values: 12 Disables XON/XOFF pacing.
13 Enables XON/XOFF pacing.
Default: 12
Result Codes: OK if <value> = 12 to 13.
ERROR if <value> 12 to 13.
&F Restore Factory Default Configuration
Description: Use this command to reset the modem to the configuration programmed at the
factory. This operation replaces all of the command options* and S-register settings
in the active configuration with factory default values.
Note: In voice mode, the command line is ignored if the AT&F command is placed on
the same line as the other commands. To load factory settings in voice mode, issue
the &F<value> command by itself.
Syntax: AT&F<value>
Values: 0 Loads factory settings as active configuration.
Default: None
Result Codes: OK if <value> = 0.
ERROR if <value> 0.
Note: There are several noted exceptions to this command and caution should be used
when determining the state of the command options once this command has been
executed.
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 65 66

Kommentare zu diesen Handbüchern

Keine Kommentare