March 2011 Page 1 of 30
FF06-2P (Version 2.07)
User Guide
2013
PLEASE NOTE: THIS PRODUCT IS NOT APPROVED FOR USE IN CHINA
All Rights Reserved (C) Copyright 2002-2011, Pushkablue Data Communications Ltd
Pushkablue Data Communications Ltd
100, Alexandra Road, Poole, Dorset, BH14 9EP, United Kingdom
Tel: +44 (0) 1202 606285
Tel from U.S.A. (Toll Free): 1 866 895 3130
Email: martin002@pushkablue.co.uk
No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic,
mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of Pushkablue Data Communications Ltd
Disclaimer
Pushkablue Data Communications Ltd makes no representations or warranties with respect to the contents hereof and specially disclaims any implied warranties or merchantability or fitness for any
particular purpose. Further, Pushkablue Data Communications Ltd reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Pushkablue Data Communications Ltd to notify any such person of such revision or changes.
Trademarks
The Trademarks of the other Corporations which may be used in this manual are hereby acknowledged.
Warning: This Product may contain chemicals Known to the State of California to cause Cancer, and/or Birth Defects or Other Reproductive harm
Specifications:
1 x Multitech MT5600SMI Internal V34 Globally approved Modem
(MT5600SMI Conformity: UL 60590-1 (UL No: E150299)
EN60950:2000, EN55022:1994+A1:1995+A2:1997
EN55024:1998, TBR21:1998, FCC Part 68)
See Multitech Declaration of Conformity on Page 29 of this document
1 x RJ45 Serial Input (9,600bps, 8, N, 1)
6 x Serial ports (Speeds 9600bps, 115,200bps)
2 x AC (C13) Input 10 Amps 100-240VAC 50-60Hz
2 x AC (C14) Output 10 Amps 100-240VAC 50-60Hz
1 x External Autosensing 100-250VAC Power Adapter 5VDC (2.6amps)
1 x DC Input 5VDC (1Amp Max)
Dimensions: 435mm (W) x 44mm (H) x 350mm (D)
1U Rackmount
Weight: 2.5Kgs ( 5.5lbs)
Enclosure: Aluminium
Humidity: 10-80% non condensing
Operating Temperature: -10 to 45º C
Conformity:
IEC 60950-1:2001
UL: 60950-1 CISPR 22/A1:2004
CISPR 24/A2:2002 FCC CFR47: Part 15: 2006
Please note: This product does not have Homologation approvals for the following countries: Mainland China, Morocco, Peru, Tunisia, and Vietnam.
Please contact Pushkablue Data Communications Ltd for homologation status.
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1 - User Guide

March 2011 Page 1 of 30 FF06-2P (Version 2.07) User Guide 2013 PLEASE NOTE: THIS PRODUCT IS NOT APPROVED FOR USE IN CHINA All Rights Reserved

Seite 2 - March 2011 Page 2 of 30

March 2011 Page 10 of 30 REMOTE POWER FUNCTIONS Power OFF Function If you wish to turn the power off to a network appliance that is connected

Seite 3 - March 2011 Page 3 of 30

March 2011 Page 11 of 30 FF06-2P Configuration There are two ways you can configure an FF06-2P. 1) Using Abbreviated Commands at the Main Menu

Seite 4 - March 2011 Page 4 of 30

March 2011 Page 12 of 30 Changing Admin 1 and 2 Names and Passwords The FF06-2P has two Administrators. This enables network operations organiza

Seite 5 - Contents

March 2011 Page 13 of 30 Add, Change & Delete Users Each Administrator (Admin 1 and Admin 2) can add up to 10 User Accounts to each. User

Seite 6 - March 2011 Page 6 of 30

March 2011 Page 14 of 30 Changing Prompt Name (Please note: <CR> = Enter) Abbreviated Command Admin 1 Admin 2 Parameters/Values Descript

Seite 7 - Accessories

March 2011 Page 15 of 30 Other Configuration commands 1) Adding & Changing Login Banner 2) Changing Disconnect character 3) Turning PB Flow

Seite 8 - Hardware Installation

March 2011 Page 16 of 30 FF06-2P Configuration Using Menus (F) - FastFix Set Up Options This section covers the (F)-FastFix Setup Options. To

Seite 9 - Basic Operations

March 2011 Page 17 of 30 (3)- Set Port Names You may wish to change the FF06-2P console port (1 to 6) names, so operators can identify the co

Seite 10 - March 2011 Page 10 of 30

March 2011 Page 18 of 30 (5) – Set Comm Port Speeds All of the console port (1 to 6) default speeds are 9,600bps. To change the console port

Seite 11 - FF06-2P Configuration

March 2011 Page 19 of 30 (6) - Set Security Keys This function is where you set up the security ID keys which work with the Pushkablue Secure A

Seite 12 - March 2011 Page 12 of 30

March 2011 Page 2 of 30 CAUTIONS, PLEASE READ BEFORE INSTALLATION 1) THIS UNIT SHOULD ONLY BE INSTALLED BY A PROFESSIONAL INSTALLATIONS ENGINEE

Seite 13 - March 2011 Page 13 of 30

March 2011 Page 20 of 30 (7) – Set Banner You can enable a banner which will appear with the Login Prompt. This Banner is to show unauthorise

Seite 14 - March 2011 Page 14 of 30

March 2011 Page 21 of 30 Changing Admin 1 Name and Passwords There are 3 ways to change the Default Admin user name and passwords 1) Using the

Seite 15 - March 2011 Page 15 of 30

March 2011 Page 22 of 30 The 3rd Option for changing the Administrator name and all security details is the use of the Pushkablue Secure Adm

Seite 16 - March 2011 Page 16 of 30

March 2011 Page 23 of 30 Set Comms Options This section explains the operations of the various Comms options available. From the Main Menu, c

Seite 17 - March 2011 Page 17 of 30

March 2011 Page 24 of 30 3) Set PB Flow Control (default: Enabled) The PB flow control feature is enabled for serial devices that do not have

Seite 18 - March 2011 Page 18 of 30

March 2011 Page 25 of 30 Pushkablue Manage Users Manage user via Menu Commands This section covers how to manage users, their passwords and the

Seite 19 - March 2011 Page 19 of 30

March 2011 Page 26 of 30 (5) Show User configuration: Type 5<CR> Shows the User number, User Name, Ports Assigned, Dial Back Number &

Seite 20 - March 2011 Page 20 of 30

March 2011 Page 27 of 30 How to Disconnect the Call There are two ways to disconnect the call 1) At the main menu of the remote FastFix type:

Seite 21 - March 2011 Page 21 of 30

March 2011 Page 28 of 30 RJ45 Serial Port Pin Outs & Standard Cable specification The TERM port and the Console port TX and RX pin outs are

Seite 22

March 2011 Page 29 of 30 Part No:FF-MCAFEE to Connect Pushkablue Console port to Any 9 Way DB Male (DTE) connection Pushkablue to McAfee Netwo

Seite 23 - Set Comms Options

March 2011 Page 3 of 30 Regulatory Compliance USA and Canada FCC Part 15 This equipment has been tested and found to comply with the limits for

Seite 24 - March 2011 Page 24 of 30

March 2011 Page 30 of 30 Multitech Internal V34 Globally Approved Modem (Part No: MT5600SMI) The FF06-2P uses the Multitech MT5600SMI Intern

Seite 25 - Pushkablue Manage Users

March 2011 Page 4 of 30 Canadian Limitations Notice Notice: The ringer equivalence number (REN) assigned to each terminal device provides an ind

Seite 26 - March 2011 Page 26 of 30

March 2011 Page 5 of 30 Contents FF06-2P Hardware Overview…………………………………………………………... Page 7 FF06-2P Hardware Installation………………………………………………

Seite 27 - March 2011 Page 27 of 30

March 2011 Page 6 of 30 Set Comms Options…………………………………………………………………………………………. Page 23-24 Set Inactivity Timeout Page 23 Set Disconnect

Seite 28

March 2011 Page 7 of 30 Hardware Overview 1- Screw Insert for DC Bracket 7- Console Ports 4 to 6 (9,600bps to 115,200bps) 2- 5V DC Con

Seite 29 - Rollover cable

March 2011 Page 8 of 30 Hardware Installation Installation of the FF06-2P is very simple. We have created a step by step graphic below for your

Seite 30 - March 2011 Page 30 of 30

March 2011 Page 9 of 30 FF06-2P Basic Operations This section describes the basic operational features and functionality of the FF06-2P. Loggi