Chapter 3 Using the Front Panel
Multi-Tech Systems, Inc. MT5600BA-V92 User Guide 24
CALLBACK SECURITY
Use and Enter to turn callback security on or off. Same as the #DB0 and
#DB1 commands. For more information about callback security, see Chapter
6, “Callback Security.”
PASSWORD SETUP
Use to enter callback security passwords in
memory locations 130. Each password must
be six to ten characters in length. To scroll
through a list of digits and characters, press
and . To go to the next position, press .
To back up or to exit without saving, press
several times. To save the password, press
Enter. Same as the #CBP= command.
CALLBACK NUMBER
Use to enter callback security phone numbers
in memory locations 130. Each number can be
up to 30 characters long. Same as the #CBN=
command. Note: Only 16 characters can be
displayed at a time. To see characters 1730,
press the button. To go to the previous LCD,
press the button. To go to the next LCD,
press the button.
S-REGISTER OPTIONS
Use , , and Enter to display the current S-register values and enter new
values. Same as the Sr? and Sr=n commands.
VIEW S-REGISTER
SETTINGS
Use and Enter to select the
number of the S-register whose value you want
displayed. To scroll through a list of digits, press
 and . To go to the next position, press
. To back up or to exit without saving, press
several times. To display the value, press
Enter. Same as the Sr? command.
SET S-REGISTER
Use and Enter to select the
number of the S-register whose value you want
to change, and the value you want to enter. To
scroll through a list of digits, press  and .
To go to the next position, press . To back up
or to exit without saving, press several
times. Same as the Sr=n command.
MONITOR OPTIONS
Use and Enter to display line quality and the line signal-to-noise ratio.
LINE QUALITY
Use and Enter to display line signal quality as
a three-digit number. The higher order byte of
the EQM value is displayed. Based on the EQM
value, retrain or fallback/fall forward may be
initiated if enabled by %E1 or %E2. Same as the
%Q command.
SIGNAL TO NOISE RATIO
Use and Enter to display the line signal-to-
noise ratio in dB.